Scanning Electron Microscope - Environmental Health and Safety (2024)

  • What is a SEM?
  • How does a SEM work?
  • How is a sample prepared?
  • What are the radiation safety concerns?
  • Scanning Electron Microscope Radiation Safety Guidelines
  • References

What is a SEM?

SEM stands for scanning electron microscope. The SEM is a microscope that uses electrons instead of light to form an image. Since their development in the early 1950's, scanning electron microscopes have developed new areas of study in the medical and physical science communities. The SEM has allowed researchers to examine a much bigger variety of specimens.

The scanning electron microscope has many advantages over traditional microscopes. The SEM has a large depth of field, which allows more of a specimen to be in focus at one time. The SEM also has much higher resolution, so closely spaced specimens can be magnified at much higher levels. Because the SEM uses electromagnets rather than lenses, the researcher has much more control in the degree of magnification. All of these advantages, as well as the actual strikingly clear images, make the scanning electron microscope one of the most useful instruments in research today.

How does a SEM work?

Scanning Electron Microscope - Environmental Health and Safety (1)


Diagram courtesy of Iowa State University

The SEM is an instrument that produces a largely magnified image by using electrons instead of light to form an image. A beam of electrons is produced at the top of the microscope by an electron gun. The electron beam follows a vertical path through the microscope, which is held within a vacuum. The beam travels through electromagnetic fields and lenses, which focus the beam down toward the sample. Once the beam hits the sample, electrons and X-rays are ejected from the sample.

Scanning Electron Microscope - Environmental Health and Safety (2)

Detectors collect these X-rays, backscattered electrons, and secondary electrons and convert them into a signal that is sent to a screen similar to a television screen. This produces the final image.

How is a sample prepared?

Because the SEM utilizes vacuum conditions and uses electrons to form an image, special preparations must be done to the sample. All water must be removed from the samples because the water would vaporize in the vacuum. All metals are conductive and require no preparation before being used. All non-metals need to be made conductive by covering the sample with a thin layer of conductive material. This is done by using a device called a "sputter coater."

The sputter coater uses an electric field and argon gas. The sample is placed in a small chamber that is at a vacuum. Argon gas and an electric field cause an electron to be removed from the argon, making the atoms positively charged. The argon ions then become attracted to a negatively charged gold foil. The argon ions knock gold atoms from the surface of the gold foil. These gold atoms fall and settle onto the surface of the sample producing a thin gold coating.

What are the radiation safety concerns?

The radiation safety concerns are related to the electrons that are backscattered from the sample, as well as X-rays produced in the process. Most SEMs are extremely well shielded and do not produce exposure rates greater than background. However, scanning electron microscopes are radiation-generating devices and should be at least inventoried. The Indiana State Department of Health requires that the machines be registered with their office using State Form 16866, Radiation Machine Registration Application. It is also important that the integrity of the shielding is maintained, that all existing interlocks are functioning, and that workers are aware of radiation safety considerations.

The main reasons for developing a SEM safety plan are:

  • to keep accurate inventory of all SEM's on campus (manufacturer/model, serial number, location, contact person and phone number)
  • to warn workers of the risk of interfering with any safety devices (investigator needs to have permission to override any interlocks or warning devices)
  • to make sure shielding is not compromised (exposure rate not greater than 0.5 mrem/hr at 5 cm from any surface of machine)
  • to let workers know who to contact in an emergency or if they have any questions

Scanning Electron Microscope Radiation Safety Guidelines

  1. Safety evaluations will be performed initially when machine is purchased and after machine has been moved.
  2. Each machine should be key controlled when not in use. Interlocks, if present, must remain operational unless approved by the RSO.
  3. Shielding must be sufficient to maintain exposure rates less than 0.5 mrem/hr at 5 cm.
  4. The Radiation Safety Office will keep inventory and survey information on file in their offices. The SEM user should keep logbook of any maintenance done on machine. RSO must be notified if any modifications are made to the interlocks or any other safety devices. The SEM user should also keep a copy of operating and emergency procedures at the accelerator panel.
  5. No survey meters or personnel dosimetry are required.

References:

  • Encyclopedia.Com
  • Iowa State SEM Homepage
  • Lawrence Livermore Radiation Safety Regulation, App. B, Summary of Radiation Generating Devices, Radiation Safety Requirements
  • Virginia Tech Radiation Safety Pages

Many thanks also to the many responses and suggestions from the members of the RADSAFE list server.

If you have any questions please contact Radiological Management.

Campus Safety Contacts

Scanning Electron Microscope - Environmental Health and Safety (3)

If you see something, say something.

Purdue Police
Phone: (765) 494-8221

Purdue Fire
Phone: (765) 494-6919

REPORT A SAFETY CONCERN

Sign up forEmergency Text Messages

Do you want to recognize one of our staff for a job well done?Nominate the staff member(s) for aBravo Award here!

Scanning Electron Microscope - Environmental Health and Safety (2024)

FAQs

Scanning Electron Microscope - Environmental Health and Safety? ›

Radiation safety concerns regarding electron microscopes are minimal, and if anything, X-ray radiation is only produced from the backscattered electrons impinging on the sample.

What are the safety precautions for scanning electron microscope? ›

Precautions: - Always wear protective clothing, including a face mask, goggles, rubber gloves, and apron when handling corrosive chemicals. - Use the chemicals only in the designated area; - Do not transport chemicals around the room in beakers. - Never pour chemicals back into the original container.

What is the purpose of environmental scanning electron microscope? ›

Environmental SEM (ESEM) is the development of a normal high-vacuum SEM. It enables wet samples to be observed through the use of partial water vapor pressure in the microscope specimen chamber.

Are scanning electron microscopes safe from radiation? ›

Scanning Electron Microscope Radiation Safety Guidelines

Each machine should be key controlled when not in use. Interlocks, if present, must remain operational unless approved by the RSO. Shielding must be sufficient to maintain exposure rates less than 0.5 mrem/hr at 5 cm.

What are the negatives of scanning electron microscope? ›

The disadvantages of SEM are its size and cost. SEM is expensive to operate. The preparation of samples can result in artifacts. A critical disadvantage is that SEM is limited to solid, inorganic samples small enough to fit inside a vacuum chamber that can handle moderate vacuum pressure.

What are 3 safety precautions when using a microscope? ›

NOTES:
  • Do not touch the glass part of the lenses with your fingers. Use only special lens paper to clean the lenses.
  • Always keep your microscope covered when not in use.
  • Always carry a microscope with both hands. Grasp the arm with one hand and place the other hand under the base for support.

What are the disadvantages of environmental SEM? ›

The main disadvantage of typical ESEM instrumentation is that the electron beam spreads in the high-pressure environmental chamber and excites fluorescent X-rays from the entire specimen, not just from under the electron beam.

When should a scanning electron microscope be used? ›

SEMs provide a high degree of analytical capability and reveal surface details at nanoscale resolution. A single greyscale image from derived from scanning electron microscopy can often be enough to achieve critical objectives, for example, the ability to visualize microstructures in a materials sample.

What is the difference between environmental SEM and SEM? ›

The main feature distinguishing ESEM from conventional SEM is the presence of a gas in the specimen chamber. Gases may include nitrous oxide, helium, argon and other, but water vapour is the most efficient amplifying gas found and the most common gas used in ESEM.

What is the radiation exposure for SEM? ›

Handled correctly (ie using a properly-assembled, certified SEM), the radiation risks are negligible. You can safely use a desktop SEM without fear of radiation sickness.

What is one significant disadvantage of scanning and transmission electron microscopes? ›

The disadvantages of a scanning electron microscope start with the size and cost. SEMs are expensive, large and must be housed in an area free of any possible electric, magnetic or vibration interference. The maintenance involves keeping a steady voltage, currents to electromagnetic coils and circulation of cool water.

What are the disadvantages of TEM? ›

The disadvantage of the TEM is that they are very large and expensive setups, which need tedious sample preparation. The operation and analysis require special training and the samples are limited to small sizes and must be electron transparent.

Is TEM a destructive technique? ›

Although atomic information can be resolved, TEM involves a destructive preparation process via mechanical polishing or focused ion beam (FIB) methods. These sample preparation methods are time consuming and an experienced experimentalist is required to achieve a high yield.

What is a major disadvantage to using a SEM or TEM microscope? ›

One disadvantage of using an electron microscope is that it is difficult to produce a three-dimensional image of the specimen.

What detectors are used in scanning electron microscopy? ›

Secondary Electron Detector (SED)

Secondary electrons are detected with an Everhart-Thornley (E-T) detector. The ET detector is composed of a scintillator inside a Faraday cage and is placed above the sample to one side.

Top Articles
Latest Posts
Article information

Author: Saturnina Altenwerth DVM

Last Updated:

Views: 6252

Rating: 4.3 / 5 (44 voted)

Reviews: 91% of readers found this page helpful

Author information

Name: Saturnina Altenwerth DVM

Birthday: 1992-08-21

Address: Apt. 237 662 Haag Mills, East Verenaport, MO 57071-5493

Phone: +331850833384

Job: District Real-Estate Architect

Hobby: Skateboarding, Taxidermy, Air sports, Painting, Knife making, Letterboxing, Inline skating

Introduction: My name is Saturnina Altenwerth DVM, I am a witty, perfect, combative, beautiful, determined, fancy, determined person who loves writing and wants to share my knowledge and understanding with you.