Design of Raft Foundations - Methods and Calculations - The Constructor (2024)

🕑 Reading time: 1 minute

According to IS – 2950:1965, the design criteria of raft footings are given below:The maximum differential settlement in foundation on clayey soils and sandy soils should not exceed 40mm and 25mm respectively. The maximum settlement should generally be limited to the following values:

  • Raft foundation on clay – 65 to 100 mm.
  • Raft foundation on sand – 40 to 65 mm.

Design of Raft Foundations - Methods and Calculations - The Constructor (1)There are two methods for the design of raft foundations. They are:

  1. Conventional Method
  2. Soil Line Method.

1. Conventional Method of Raft Foundation Design

Assumptions:

1. The soil pressure is assumed to be plane such that the centroid of the soil pressure coincides with the line of action of the resultant force of all the loads acting on the foundation.2. The foundation is infinitely rigid and therefore, the actual deflection of the raft does not influence the pressure distribution below the raft.In this method, allowable bearing pressure can be calculated by the following formulae:Design of Raft Foundations - Methods and Calculations - The Constructor (2)Design of Raft Foundations - Methods and Calculations - The Constructor (3)Where Design of Raft Foundations - Methods and Calculations - The Constructor (4) and Design of Raft Foundations - Methods and Calculations - The Constructor (5) = allowable soil pressure under raft foundation in Design of Raft Foundations - Methods and Calculations - The Constructor (6) (use a factor of safety of three). The smaller values of Design of Raft Foundations - Methods and Calculations - The Constructor (7) and Design of Raft Foundations - Methods and Calculations - The Constructor (8)should be used for design.Design of Raft Foundations - Methods and Calculations - The Constructor (9)and Design of Raft Foundations - Methods and Calculations - The Constructor (10)= reduction factor on account of subsoil water.N = penetration resistance.If the values of N is greater than 15 in saturated silts, the equivalent penetration resistance should be taken for the design. The equivalent penetration resistance can be determined by the formula:Design of Raft Foundations - Methods and Calculations - The Constructor (11)The pressure distribution (q) under the raft should be calculated by the following formula:Design of Raft Foundations - Methods and Calculations - The Constructor (12)Where Q = total vertical load on raftx, y = co-ordinates of any given point on the raft with respect to the x and y axes passing through the centroid of the area of the raft.A = total area of the raft.Design of Raft Foundations - Methods and Calculations - The Constructor (13)= eccentricities about the principal axis passing through the centroid of the section.Design of Raft Foundations - Methods and Calculations - The Constructor (14) = moment of inertia about the principal axis through the centroid of the section.Design of Raft Foundations - Methods and Calculations - The Constructor (15),Design of Raft Foundations - Methods and Calculations - The Constructor (16) can be calculated by the following equations:Design of Raft Foundations - Methods and Calculations - The Constructor (17)Design of Raft Foundations - Methods and Calculations - The Constructor (18)Design of Raft Foundations - Methods and Calculations - The Constructor (19)Design of Raft Foundations - Methods and Calculations - The Constructor (20)Where Design of Raft Foundations - Methods and Calculations - The Constructor (21)and Design of Raft Foundations - Methods and Calculations - The Constructor (22)= eccentricities in x and y direction of the load from the centroid.Design of Raft Foundations - Methods and Calculations - The Constructor (23)and Design of Raft Foundations - Methods and Calculations - The Constructor (24)= moment of inertia of the area of the raft respectively about the x and y axes through the centroid.Design of Raft Foundations - Methods and Calculations - The Constructor (25) for the whole area about x and y axes through the centroid.

2) Soil line Method (Elastic Method) of Raft Foundation Design

A number of methods have been proposed based on primarily on two approaches of simplified and truly elastic foundations.i. Simplified elastic foundation: The soil in this method is replaced by an infinite number of isolated springs.ii. Truly elastic foundation: The soil is assumed to be continuous elastic medium obeying Hooke’s law.In the case of foundation which is comparatively flexible and where loads tend to concentrate over small areas these methods are to be used. The method assumes in addition to other factors that the modulus of subgrade reaction, determined from tests is known. The modulus of subgrade reaction (Ks) as applicable to the case of load through a plate of size 30 cm x 30 cm or beams 20 cm wide on soil area is given in table-1 for cohesionless soils and table-2 for cohesive soils.Table -1: Modulus of subgrade reaction Ksfor cohesionless soils

Soil CharacteristicsKs(Kg/cm2)
Relative DensityValues of NDry or moist stateSubmerged state
1. Loose<101.50.9
1. Medium10 to <304.72.9
3. Dense30 and over1810.8

Table – 2: Modulus of subgrade reaction Ksfor cohesive soils

Soil CharacteristicsKs(Kg/cm2)
ConsistencyUnconfined compressiveStrength (Kg/cm2))-
1. Stiff1 to <22.7
1. Very Stiff2 to <45.4
3. Hard4 and over10.8

The above values of Ksare corresponding to a square plate of size 30 cm x 30 cm. To find the values of K corresponding to different sizes and shapes, the following relationships to be used.(a) Effect of sizeDesign of Raft Foundations - Methods and Calculations - The Constructor (26) for cohesionless soilDesign of Raft Foundations - Methods and Calculations - The Constructor (27) for cohesive soils.Where, K = modulus of subgrade reaction for footing of width B cmKs= modulus of subgrade reaction for a square plate of width 30cm x 30cmK’ = modulus of subgrade reaction for footing of width Design of Raft Foundations - Methods and Calculations - The Constructor (28)cm.(b) Effect of shapeDesign of Raft Foundations - Methods and Calculations - The Constructor (29) for cohesive soilsWhere Design of Raft Foundations - Methods and Calculations - The Constructor (30)= modulus of subgrade reaction for a rectangular footing having length L and width B.Design of Raft Foundations - Methods and Calculations - The Constructor (31)= modulus of subgrade reaction for square footing of side B.The effect of shape is negligible in the case of footing on cohesionless soils.

Design of Raft Foundations - Methods and Calculations - The Constructor (2024)
Top Articles
Latest Posts
Article information

Author: Dean Jakubowski Ret

Last Updated:

Views: 5783

Rating: 5 / 5 (50 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Dean Jakubowski Ret

Birthday: 1996-05-10

Address: Apt. 425 4346 Santiago Islands, Shariside, AK 38830-1874

Phone: +96313309894162

Job: Legacy Sales Designer

Hobby: Baseball, Wood carving, Candle making, Jigsaw puzzles, Lacemaking, Parkour, Drawing

Introduction: My name is Dean Jakubowski Ret, I am a enthusiastic, friendly, homely, handsome, zealous, brainy, elegant person who loves writing and wants to share my knowledge and understanding with you.